• Stainless Steel Autoclave Sterilizer with 1200mm Diameter 3000 Length
  • Stainless Steel Autoclave Sterilizer with 1200mm Diameter 3000 Length
  • Stainless Steel Autoclave Sterilizer with 1200mm Diameter 3000 Length

Stainless Steel Autoclave Sterilizer with 1200mm Diameter 3000 Length

After-sales Service: 5 Years
Warranty: 10 Years
Customized: Customized
Certification: CE, CE, FDA
Scale: Small
Automation: Automatic
Customization:

Contact Supplier

Gold Member Since 2016

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company

Basic Info.

Model NO.
DN1200 autoclave sterilizer
Principle
Static
Structure
Chamber Sterilization Retort
Operation
Intermittent
Energy
Heat Sterilization
Property
Physical Sterilization
Type
High Temperature High Pressure Sterilization, Pressure Steam Sterilization Equipments
Theory
Autoclave
Electric Tension
220V
LCD Display
with LCD Display
Ultra High Temperature Alarm
Ultra High Temperature Alarm
Sterilization Information Recording and Printing
Sterilization Information Recording and Printing
Material
Stainless Steel
Sterilizer Construction Material
Stainless Steel
Batch Sterilization Capacity
100L ~ 5000liter
Sterilizer Chamber Layout
Horizontal / Vertical
Heating Medium
Steam / Electric
Max Sterilization Temp.
125 Degree C
Max Working Pressure
0.35 MPa
Energy Recovery
with Heat Recovery Tank
Plate Heat Exchanger
Optional
Wter Inlet Pump
Available
Back Pressure by
Compressed Air
Transport Package
Wooden / Nylon
Specification
water spray, with 2 sterilization baskets, 100L~5T
Origin
China
HS Code
84198990
Production Capacity
2000PCS Every Season

Product Description

Sterilizer autoclave is a pressure chamber used to carry out industrial processes requiring elevated temperature and pressure different to ambient air pressure. Autoclaves are used in food factory to eliminate the harmful bacteria in canned food, mushroom glass jar, egg vacuum packing, vacuum packed rice, and fish tin can. In medical applications autoclaves are used to perform sterilization; and in the chemical industry to cure coatings, vulcanize rubber and for hydrothermal synthesis.
Stainless Steel Autoclave Sterilizer with 1200mm Diameter 3000 Length


Many autoclaves are used to sterilize equipment and supplies by subjecting them to high pressure saturated steam at 121 °C (249°F) for around 15-20 minutes depending on the size of the load and the contents.  But in some start-up business firms and Laboratory for big food factory, electric heating type autoclave are widely used.
Electric Heating Sterilizer autoclave (back pressure sterilization equipment)
Electric heating sterilizer autoclave that we can offer have different configuration, for example, the layout of the sterilizer autoclave vessel may different a lot. Most of our sterilizer autoclave are designed according buyers request. Here now we list our some commonly used layout of high pressure sterilizer autoclave for your reference:
  1. Series No. R-S (horizontal sterilizer autoclave with single sterilization vessel)
This series have 2 hot sell sterilizer autoclaves, we give them different Reference No. to distinguish them:
  • Ref. No. S E S.
Single vessel sterilizer autoclave with electric heating and water sprayer.
Here the first "S" means the sterilizer autoclave vessel is single---single vessel and single wall, no thermal insulation material used. "E" stands for the heating mode of this sterilizer autoclave is electric. At the bottom of the sterilizer autoclave, there will be 2 or 3 electric heating tubes. The last letter "S" tells about the way of heat transfer in the sterilizer autoclave. When this sterilizer autoclave working, the steam jet and / or water droplets will spray out towards the content in the sterilization chamber to generate an evenly heating.
  • Ref. No. S V S.
While the above mentioned sterilizer autoclave use steam heating rather than electric, we change the middle letter "E" in the Ref. No. resulting a new sterilizer autoclave which is heated by steam vapor, single sterilization vessel with sprayer.
 
  1. Series No. R-I (Horizontal sterilizer autoclave with insulated sterilization vessel)
This series have 3 hot sell sterilizer autoclaves, here we list the reference No. for your reference.
  • Ref. No. E S
This ref. No. stands for an insulated sterilizer autoclave heated by electric, with steam sprayer. Steam or hot water usually spray out from the top of the inner sterilizer autoclave chamber. Under request, we can made it into top and side spray type.
  • Ref. No. T S  
This ref. No. shows us the sterilizer autoclave is electric heating type with sprayer. Compared with the sterilizer autoclave mentioned above, this sterilizer autoclave have an insulated water storage tank besides the sterilization pot. This sterilization structure is commonly used in factories which have limited height for the sterilizer autoclave.
  • Ref. No. O S
This reference No. will introduce a hot sell sterilizer autoclave to us --- the overlay type sterilizer autoclave. The sterilization vessel was heated by electric, with steam / hot water sprayer, with insulated sterilization pot. What's more, it comes with high level water tank on the sterilization pot. That means the water recycle tank was fixed on the top of the sterilization vessel. It is one on another instead of one beside another.  
All the above listed sterilizer autoclaves are water spray type. Water immersion type sterilizer autoclave and water circulation type sterilizer autoclave are also in our business scope. No mater you need water spray sterilizer autoclave, water immersion sterilizer autoclave or water circulation sterilizer autoclave, the heating medium can be all saturated steam at 121 °C. all of them use counter pressure to protect your product from got broken due to the pressure in the sterilization process.

 Accessories for steam spray sterilizer autoclave retort
  • Pressure gauge
  • Temperature thermometer
  • Safety valve
  • Safety lock
  • Gasket sealing ring
  • Pressure relief valve
  • Compressed air inlet valve
  • Water inlet pump
  • Steam inlet valve and by pass valve (optional)
  • Pipe filter for cooling water
  • Filter screen for water outlet pipe (optional for glass jar sterilizer autoclave)
  • Countdown Timer for sterilization period / cooking phase
  • Level meter
  • Plate heat exchanger (optional)
  • Round Paper recorder / paper less recorder (optional)
  • USB Date logger (optional)
  • Insulated Hot water tank (optional)
  • Conveyor Chain inside the sterilizer autoclave retort (optional)
  • PLC control system (optional)
  • Air compressor
  • Compressed air storage tank

Steam-Spray-Counter Pressure Retort sterilizer autoclave
Steam Water Spray Retort
Retort sterilizer autoclave is also called sterilizer autoclave or sterilization retort. In some country and area, sterilizer autoclave also being referred to as autoclave or autoclave sterilizer autoclave. Clave is also being used as the name of a sterilizer autoclave.
We can see many different packing and package for fruit, juice, meat and fish, tin can, glass jar, PP bottle, vacuum packagemost of them need to be sterilized before they are send to supermarket. A sterilizer autoclave is the right machine which used to sterilize the above mentioned products.
Hot Sell Sterilizer autoclave Customer Case
Customer request
  1. electric water spray autoclave
  2. for C-PET plastic trays containing tofu
  3. tray size 150 × 130 × 45mm  
  4. around 200 trays each batch
  5. use 380V 50Hz 3phase power supply
  6. 121degree C sterilization temperature
Suggested Autoclave / Sterilizer autoclave price (FOB Ningbo)
No. Item Unit price Amount
1 DN800×1000 - CE
electric heating water spray
**,8** usd **,8** usd
Autoclave / Sterilizer autoclave specification
Retort capacity 500L
Productivity cans/batch 192 trays
for 150 × 130 × 45mm trays
Pot size  Φ800*1000 mm
Design temperature 143 0C
Operating temperature ≤138 0C
Design pressure  0.3mpa
Working pressure  ≤0.26Mpa
Heating method Electric
Heating power ≤36KW
Material SUS304
Raw material thickness 7mm
Thermal insulation 50mm PU insulation with 1.5mm cladding
Welding coefficient 0.7
Corrosion allowance 1mm
Exhaust diameter() DN32-40
Cold and hot water connection tube diameter DN40-50
Overflow pipe diameter() DN25-50
Drain-pipe diameter () DN40-50
Relief valve diameter() DN25-50
Compressed air diameter() DN15-20
Adjust mouth diameter() DN25-40
Weight(kg) 500
Overall dimension L×W×H 1500×1200×1200 mm
Design life 12 years
 
Sterilizer autoclave working flow
Steam spray sterilizer autoclave / steam heating sterilizer autoclave use steam jet to heat the content to about 121 degree C for 10 to 30 minutes. After cooling, cool water or ice water was introduced to the sterilizer autoclave chamber for a rapid cooling. After the cooling process, we finished the sterilization batch. So, a steam heating / steam spray sterilizer autoclave working process should be like this:
  • Loading glass jar / fish tin can or any other package into the autoclave basket.
  • Push the sterilization baskets into the sterilizer autoclave chamber and seal the door.
  • Pump process water into the sterilizer autoclave body.
  • Turn on the steam inlet valve to start the pre-heating process.
  • When temperature arrived to 121 degree, turn down the steam inlet valve and keep the temperature at 121 degree C without any significant increase.
  • Add some compressed air into the retort or open the pressure relief valve to control the pressure at a suitable level.
  • Pump cooling water to the retort chamber or plate heat exchanger (if exist) for cooling
  • Unloading the tin can / glass jar / bottle and finish the sterilization batch
Explain of steam spray retort sterilizer autoclave / sterilizer autoclave retort / sterilization retort
When steam spray sterilizer autoclave working, directly injected steam blends with fine droplets of the water spray and results in an extremely homogenous heat transfer environment throughout the whole autoclave / sterilizer autoclave / retort sterilizer autoclave. As water jets spray into the sterilization baskets from its top and the sides as well, even and rapid heating and cooling process will be achieved.
Counter Pressure in sterilizer autoclave retort
During the preheating process, counter pressure will be unnecessary. After the content in sterilizer autoclave being heated to 121 degree C or any other sterilization temperature, the counter pressure will be needed especially in the sterilization process of glass bottle and tin can. The counter pressure is mainly generated from the compressed air. This pressure will help to keep the bottle cap stay at the bottle without flip out due to the inner bottle pressure. That is to say, counter pressure during the sterilization process will help the autoclave users increase the sterilization efficiency.
Compressed air is also being used as a force to press out the hot water and cool water from the sterilizer autoclave body to the hot water or cold water storage tank.
Benefits of water spray sterilizer autoclave
  • Quick heating in preheating process
  • uniform heat distribution in sterilizer autoclave chamber
  • Rapid and even cooling.
  • Low electricity, steam and water consumption.
  • Safe counter pressure control during all process phases.
  • Accurate temperature control
  • Suitable for different types and sizes of package.
 
Stainless Steel Autoclave Sterilizer with 1200mm Diameter 3000 Length


Price for sterilizer autoclave retort sterilization machine
Due to the diameter and the length of the sterilizer autoclave retort various for different usage, the price of our retort sterilizer autoclave will be different. In order to offer you an accurate price, please let us know your request of the sterilizer autoclave diameter and the length of the sterilization machine body. Or you can tell us the dimension of your product package and its quantity you want to sterilize per batch. We will offer you the most suitable solution and the price.

Send your message to this supplier

*From:
*To:
avatar Mr. Tonny
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now