Customization: | Available |
---|---|
After-sales Service: | 5 Years |
Warranty: | 10 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1 | Model | RV-400 | |
2 | Full capacity | 80L | |
3 | Sterilization basket capacity | 35L | |
4 | Certificate | CE ISO9001 | |
5 | Internal Diameter (mm) | 400 | |
6 | Temperature Control | Semi-automatic | |
7 | Design Temperature | 147 ºC | |
8 | Working Temperature | 121 ºC | |
9 | Design Pressure | 0.3 MPa | |
10 | Working Pressure | 0.25 MPa | |
11 | Working Medium | water, steam, compressed air | |
12 | Heating type | Electric heating | |
13 | Power consumption | 6~18KW/H | |
14 | Power supply | 220V 60Hz 3phase | |
15 | Main Pressure Part Material | Stainless steel 304 | |
16 | Construction material thickness | 4 mm | |
17 | Net Weight (kg) | 90 (by estimate) | |
18 | External Dimensions | length | 1050 mm |
Width | 600 mm | ||
height | 1100 mm |
S.N. | Item | Description | Detailed information |
1 | Ball valve A | 3/4" SS304 female thread |
Water inlet valve, used to feed water into the retort chamber. Also, cooling water will be pumped in through this valve. |
2 | Ball Valve B | 3/4" SS304, female thread | Compressed air inlet valve, before you start to use this machine, please connect this pipe to your compressed air resource. You will need 8×5.5mm hose to combine this valve together with the compressed air resource. |
3 | Ball valve C | 3/4" SS304, female thread | Pressure Relief Valve, used to release the extra pressure in the retort chamber. When inner retort pressure is higher than the needed pressure, you can open this valve to release the inner pressure. Please close this valve when inner pressure reduced to the acceptable range. |
4 | Pressure gauge | 1/4" , female thread |
Used to show the inner pressure. For most of food product, pressure usually to be 0.1Mpa to 0.25Mpa |
5 | Thermometer | M27 | Used to show the inner retort temperature |
6 | Temperature prober | Used to monitor inner retort temperature, and send the signal to the recorder. | |
7 | Safety valve | DN15 | Used to control the inner pressure automatically. When inner retort pressure is higher than 0.25Mpa, this valve will be open automatically. This is in order to protect your product and the retort. |
8 | Level meter | Glass level meter with stainless steel shell. We offer you an extra glass tube as spare |
|
9 | Level switch prober | Used to monitor inner retort lowest water level. When water level is lower than this prober, system will alarming to reminder you add water or stop heating. | |
10 | Heating tubes | 2pcs, 9kw each |
Made of full stainless steel. You can start the heating tubes one by one or use them together. The switches for them can be found on control panel. |
11 | Timer | Used to monitor the sterilization time. When sterilization time finished, system will alarming. Sterilization time is configurable. | |
12 | Temperature gauge | Show current temperature and preset the sterilization temperature. | |