Plate Heat Exchanger
This is a 12 square meter plate heat exchanger.
this heat exchanger have 57 exchanger plate , each plate have 0.22 square meter heat exchange area.
you can use this plate heat exchanger cooling 1500L 35 degree C hot water to 3 degree C in hour hour's time using 0 degree glycol water
here below is the 12 M2 plate heat exchanger specification in detail
Used to cooling 1.5T/H 35ºC CSD to 3ºC by 0 degree ice water <0ºC 1.5T/H> |
Hot side liquid inlet |
ºC |
35 |
Hot side liquid outlet |
ºC |
3 |
Cold side liquid inlet |
ºC |
0 |
Cold side liquid outlet |
ºC |
32 |
Flow rate for hot side liquid |
T/H |
1.5 |
Flow rate for cold side liquid |
T/H |
1.5 |
Average temperature difference |
Δt |
3 |
Chosed K value |
|
1500 |
Actual values of K |
cal/m2 °c |
1449 |
Single plate heat exchange area |
m2 |
0.22 |
Total heat transfer area |
m2 |
12 |
Hot liquid flow rate in PHE |
M/S |
0.2 |
Cold liquid flow rate in PHE |
M/S |
0.2 |
Designed pressure |
MPa |
0.5 |
Test pressure |
MPa |
0.75 |
Theoretical Weight |
KG |
250 |
Non-contact part material |
Covered by SS304 |
Contact part material |
SUS304 |
Gasket material |
NBR |
Connection type and pipe size |
Tri-clamp φ38 |
|
|
in order to offer you a suitbale plate heat exchanger, we need to know the following details
1. what kind of liquid you are going to heat or cool in this plate heat exchanger
2. what kind of liquid you are going to use for cooling or heating in this plate heat exchanger
3. what is the hot side liquid inlet temperature for this plate heat exchanger
4. what is the cold side liquid inlet temperature for this in this plate heat exchanger
5. what is the hot side liquid flow rate when pass through the plate heat exchanger
6. what is the cold side liquid flow rate when pass through the plate heat exchanger
7. what is the pressure for the hot liquid when it was injected into the heat exchanger
8. what is the target temperature you want to get after yoru product pass through this plate heat exchanger
the above questions are very importent because they will help us know your reqeust well and than we can offer you the suitable plate heat exchanger. you know, a suitable plate heat exchanger will save your cost.
it is unnecessary to list all the ansers when you want to get a quote for a plate heat exchanger, 3 to 5 answers will be good enough.
please be noted that we are professional supplier of plate heat exchanger, we do not want to offer you a plate heat exchanger by random. only after we know your request well can we offer you a suitable plate heat exchanger.
Common gasket for plate heat exchanger and the Max temperature the gasket can bear |
NBR |
120 degree C |
EPDM |
160 degree C |
FKM |
250 degree C |
if you know how many square meter heat exchanger area, that is very good, and we can offer you a price immediately after get the heat exchanger area.
Words in the End
Your feedback is more than important to us.
Please be noted that we aim to provide exceptional service and care to every customer we work with, and we truly appreciate you taking the time to tell us about your idea on above product details.
We are ready to answer your call and questions anytime.
offer plate heat exchanger with different heat exchanger area