Specification for 2000L mixing tank
Material |
SS304 |
Thickness |
6mm |
Capacity |
2000L |
Total capacity |
2300L |
Diameter |
1400mm |
Inner height |
1700mm |
Mixing type |
Scraper mixer |
Mixing speed / power |
36rpm 7.5KW |
High shear mixer |
2800rpm 7.5KW |
Orifice table |
Item |
Size |
Connection type |
Usage / function |
N1 |
Diameter DN50 |
Clamp connection |
Water inlet pipe |
N2 |
Diameter DN50 |
Clamp connection |
Mixture discharge |
T <PT100> |
Diameter 1/2" |
Thread connection |
Temperature gauge |
CUSTOMIZED AGITATION SOLUTIONS
Complete customized agitation solutions are designed for each tank to mix and blend as required for our customer's application, taking into account factors such as batch size, viscosity of the product, etc. All mixers are installed and verified prior to shipment. Agitators are fabricated using materials and finishes that match the tank interior. These mainly include: SS 304L agitators and 316L stainless steel agitators
HEATING & COOLING
- Dimple jacket
- Half pipe coil
- Internal pipe coil
- Open jacket
Ranking Team provides various options to support a wide range of heating and cooling requirements. We work with our customers to design the best solution for the application while keeping costs down and efficiencies up.
• Dimpled heat transfer surface
• Half pipe coil
• Full internal pipe coil
• Open jacket
• Heat trace, cables, blankets
• Double wall construction
• Outer jacket
• Sweep and scrape mixers
• Thermometers and controls
Ranking Team Engineers perform ASME and custom process calculations such as flow rate and pressure drop to determine heat transfer requirements. We also consider variables, such as:
• How the tank will be used (hot, cold or both).
• Will there be multiple batch sizes in the same tank?
• Does the customer have a preference - dimple or half pipe?
• Will the temperature cycle hot to cold?
• What is the flow rate requirement?
• Will the tank be insulated and jacketed?
• Will a sweep or scrap mixer be needed to assist with heat transfer?
Ranking Team personnel will consider these questions and more to propose a solution that will meet customer requirements and applicable Codes, operate efficiently, and be cost effective.